Skip to product information
1 Phase 220V to 3 Phase 220v  VFD Inverter Frequency Converter 50hz to 60hz Variable Frequency Drive

1 Phase 220V to 3 Phase 220v VFD Inverter Frequency Converter 50hz to 60hz Variable Frequency Drive

$297.50 USD
Specification

SPECIFICATIONS

Application: Motor,Induction Motor

Brand Name: HUABANG

Capacity: 0.75-5.5KW

Certificate: CE ROHS ISO9001:2015

Certification: CCC

Control Mode: VFD

Display: LED

IP Level: other

Model Number: V600

Nominal Voltage: 1 phase 220V to 3 phase 220v

Place of Origin: Zhejiang, China

Power Phase Number: 1 phase 220V to 3 phase 220v

Protection: emi filter, short circuit, thermal, overvoltage, input phase lacking

Rated Power: 0.75-5.5KW

Size: other

Type: VFD

Warranty: 12 Months

Company Information
100.png

China National Accreditation Service for Conformity Assessment.

 

CNAS confirms its ability to carry out appropriate conformity assessment activities.

 

HUABANG ENERGY METER TEST REPORT UNDER THIS ORGANIZATION

101.png

EU legislation, mainly used to regulate the electrical and electronic products, materials and process standards, making it more conducive to human health and environmental protection

 

HUABANG UNDER THE RoHS 2 DIRECTIVE 2011/65/EU

103.png

“Conformite Europende”

 

102.png

ISO 9001 is a standard that sets out the requirements for a quality management system. It helps businesses and organizations to be more efficient and improve customer satisfaction.

 

HUABANG PRODUCTION ACTIVITY REFERENCE IS09001: 2015

LOGO_new.jpg

By the Alibaba platform authority strength verification of high-quality suppliers, through the online and offline combination of the way, the platform for business enterprise qualifications, commodity qualifications, enterprise capabilities and other all-round strength of certification and strength transmission

 

V600 IGBT Inverter

V600 Full version__01.png

1.1 Precautions 

 

1.1.1 Motor insulation check 

Motor in the first use, long time after the re-use and regular inspection, should do motor insulation inspection, to prevent damage to the VFD Inverter due to the insulation failure of the motor winding.

Insulation inspection must be separated from the VFD Inverter, it is recommended to use a 500V voltage type Mega-European table, should ensure that the measured resistance is not less than 5M.

1.2.2 Thermal protection of the motor

If the motor does not match the rated capacity of the VFD Inverter, especially when the rated power of the VFD Inverter is greater than the motor rating, it is necessary to adjust the motor protection related parameter sits in the VFD Inverter or install thermal relays in front of the motor to protect the motor.

1.2.3 Operation above power frequency 

This VFD Inverter provides output frequencies ranging from 0Hz to 3000Hz. If the customer is required to operate above 50/60Hz, consider the resilience of the mechanism.

1.2.4 The vibration of the mechanical device 

The VFD Inverter may encounter the mechanical resonance point of the load unit at some output frequencies and can be avoided by setting the jump frequency parameters in the VFD Inverter.

1.2.5 About motor heat and noise 

Because the VFD Inverter output voltage is a PWM wave with a certain harmonic, the motor's temperature rise, noise and vibration will increase slightly compared to the frequency of work.

1.2.6 Cases with pressure-sensitive devices on the output side or capacitors that improve power factor

The VFD Inverter output is a PWM wave, the output side, such as the installation of an improved power factor capacitor or lightning-proof varistor, etc., easy to trigger the VFD Inverter instantaneously over The current even damages the VFD Inverter.

Please do not use.

1.2.7 The contactor and other switch equipment used on VFD Inverter input and output terminal

If a contactor is installed between the power supply and the VFD Inverter input, this contactor is not allowed to control the VFD Inverter start-stop. It must be necessary to use this contactor to control the VFD Inverter start and stop, the interval should not be less than one hour. Frequent charge and discharge tend to reduce the life of capacitors in the VFD Inverter. Switching devices such as contactors are installed between the output and the motor, so that the VFD Inverter should be used to break off when there is no output, otherwise it is easy to damage the module inside the VFD Inverter.

1.2.8 Use other than the rated voltage value

It is not suitable for the use of V600 series VFD Inverters outside the permissible operating voltage range specified in the manual, which can easily cause damage to the devices in the VFD Inverter. If you need to To do so, use the appropriate boost or lowering device for the variable pressure treatment.

1.2.9 Change of three-phase input to two-phase input

Do not change the VFD Inverter to two-phase use. Failure will cause failure or damage to the VFD Inverter.

1.2.10 Lightning Impact Protection

This series of VFD Inverters is equipped with lightning overcurrent protection device, for the sensor has a certain self-protection capability.

For lightning frequency place, customers should also add protection front of the VFD Inverter.

1.2.11 Altitude and derate use

In areas with altitudes above 1000m, it is necessary to derate the use due to poor cooling of the VFD Inverter due to thinning air.

Please consult our company for technical advice on this situation.

1.2.12 Some Special Uses

If the customer is required to use methods other than the suggested wiring diagram provided in this manual, such as the Common dc bus, please consult our company.

1.2.13 Attention when scrapping VFD Inverters

Electrolytic capacitors in the main circuit and electrolytic capacitors on the printing plate may explode when burned, and plastic parts can produce toxic gases when burned, so treat as industrial waste.

1.2.14 About the adaptable motor

1) the standard adaptable motor is a quadratic rat cage asynchronous induction motor. If not the above motor please be sure to according to the motor rated current optional VFD Inverter.

2) The cooling fan and rotor shaft of the non-variable motor are coaxial connections, the fan cooling effect is reduced when the speed is reduced, therefore, the field where the motor overheats should be fitted with a strong exhaust fan or replaced with a variable frequency motor;

3) The inverter has built-in standard parameters of the adaptable motor, according to the actual situation it is necessary to identify the motor parameters or modify the default value to meet the actual value as far as possible, otherwise it will affect the operation effect and protection performance;

4) The short circuit of cable or motor can cause the inverter to alarm, or even blow up the machine. Therefore, first of all, the initial installation of the motor and cable into the insulation short circuit test, daily maintenance also need to be carried out frequently this test. Note that it is important to disconnect the drive from the part of the test when doing this test.V600 Full version__09.pngV600 Full version__10.pngV600 Full version__11.pngV600 Full version__12.pngV600 Full version__13.pngV600 Full version__14.pngV600 Full version__15.pngV600 Full version__16.png

 

 

.jpg

 REAL WIRING DIAGRAM QQ20201130100016.png

 

PACKAGING 

 

QQ20201130100030.png

 

WORKSHOP 

 

100 (1).png

 

 

APPLICATION 

 

100 (2).png 

Our Services

We supply product with good quality and services as:

 

SERVICE

MOQ

OEM

 

ODM

 

 

Product Warranty Card:

 

Customer information

Company name

 

Company address

 

Contact person

 

Tel

 

Product information

Model No.

 

Bar code

 

Place of your purchase

 

Failure information

Maintenance time and content

 

 

Contacts:

 

1.jpg 

FAQ

 1. Q: Why choose us?

    A: We are professional energy meter manufacturer since 1992 conform to ISO9001 production procedure, All product has CE ROHS 

2. Q: Do you have any certificates

    A: We have CE, RoHS, CCC, CQC, ISO9001:2015 Certification.

3. Q: How about your products quality inspection?

    A: We have FULL TIME QA and QC person, 100% product need through 2 inspections and 1 spot check, the proportion conforms to the industry standard

4. Q: Can you accept OEM ODM ?

    A: we accept OEM production and can make customized product.

5. Q: What’s your quality guarantee?

    A: we provide repair or replace service within 18 months if product have quality issue and working  improperly. ( hardware damage casued by human damage and misoperation is not supported )

You may also like